Utilization of Sensors for Semiconductor Fabrication Equipment

Many steps in semiconductor manufacturing require accurate, high-speed measurement of force, torque and position. These processes also have many application-specific requirements.

UNIPULSE manufactures the following products, many of which are used in semiconductor manufacturing:

  • Load cells for force measurement
  • Torque meters for torque measurement
  • Non-contact displacement sensors for position measurement
  • Indicators compatible with these sensors

Sensor Applications in Semiconductor Manufacturing Equipment

Wafer Preparation and Front-End Processing:
Processes for preparing silicon wafers and forming electronic circuits on them. (Click an illustration for details.)
1. Ingot Pulling
2. Ingot Slicing
3. Grinding & Polishing
4. Exposure
5. Etching
6. Ion Implantation & Deposition
7. Planarization
8. Wafer Inspection

Back-End Processing (Assembly, Packaging and Testing):
Processes for turning fabricated wafers into packaged ICs and testing them. (Click an illustration for details.)
9. Dicing
10. Die Bonding
11. Wire Bonding
12. Molding
13. Final Inspection




1Ingot Pulling

One method of producing single-crystal silicon ingots involves bringing a seed crystal into contact with molten silicon in a crucible, then slowly pulling it upward while rotating it. The silicon solidifies into a cylindrical ingot as it is pulled. By measuring the weight of the growing ingot and adjusting the pulling speed accordingly, the ingot diameter can be kept constant and quality can be improved.
A load cell and a load cell indicator are used for high-accuracy weight measurement.

2Ingot Slicing

When an ingot is sliced with a wire saw, wire deflection or vibration can cause waviness on the cut surface.
Monitoring and controlling the wire tension using a load cell and a load cell indicator can help prevent this.

3Grinding & Polishing

Wafer surfaces must be planarized to nanometer-scale flatness. A load cell and a load cell indicator are used to precisely control the force applied by the grinding wheel.
Sensors are also used to monitor the amount of polishing agent applied, measure dimensions after polishing, and inspect wafer warpage.

4Exposure

During semiconductor manufacturing, exposure systems transfer various patterns onto wafers. Positioning errors between process steps must be limited to only a few nanometers. Wafer stages also undergo repeated acceleration and deceleration.
Non-contact capacitive displacement sensors are used for precise, high-speed positioning under these conditions.

5Etching

In plasma etching equipment, the gap between the electrode and the wafer affects plasma density and electric field distribution. Non-contact capacitive displacement sensors are used to measure this gap with high accuracy.

6Ion Implantation & Deposition

Traditionally, experienced operators determined when to clean the inside of deposition equipment based on operating hours. The wafer-release mechanism is actuated from outside the vacuum chamber through a rotary mechanism. Measuring its torque with a torque meter allows cleaning intervals to be determined quantitatively, improving production efficiency.

7Planarization (CMP; Chemical Mechanical Polishing)

Repeated exposure, etching and deposition steps create an uneven wafer surface. Chemical mechanical polishing (CMP) planarizes this surface to a flatness of a few nanometers. A load cell and a load cell indicator are used to precisely control the force applied by the polishing pad.

8Wafer Inspection

In semiconductor manufacturing and inspection equipment that uses optical microscopes, non-contact capacitive displacement sensors can enable high-speed focusing.
Load cells are also used to measure probe contact force, while displacement sensors are used to measure wafer thickness.

9Dicing

Excessive blade load during wafer dicing can cause edge chipping or internal cracks.
Load cells and torque meters are used to precisely control the load and maintain a stable feed rate.

10Die Bonding

To attach a chip at the designated position on a lead frame, a load cell can be installed in the die bonder head or nozzle to monitor the bonding force in real time.

11Wire Bonding

When connecting a chip to a lead frame with bonding wires, controlling the bonding force is essential to ensure reliable bonds while preventing chip damage.
A load cell and a load cell indicator are used to check this force.

12Molding

If the mold-clamping force is insufficient, the pressure of the injected resin can open a gap in the mold, allowing resin to escape and form flash.
A load cell and a load cell indicator are used to monitor the clamping force.

13Final Inspection

Force testing and monitoring are used in a wide range of electrical, visual and structural inspections.
Examples include measuring loads during mechanical stress tests, checking whether probe contact force is within acceptable limits, and measuring contact force during continuity tests. Load cells and load cell indicators are used for these applications.

Other applications include measuring the gripping force of wafer-handling robots (AGV/AMR), monitoring the amount of gas remaining in cylinders by weight, controlling the amount of photoresist dispensed, and calibrating force sensors built into die bonders.
UNIPULSE offers sensors for demanding semiconductor manufacturing applications, including models for high-temperature or vacuum environments and siloxane-free load cells.