Product outline

FC400-PRT-FA is a compact type indicator equipped as standard with PROFINET IO interface.

High sampling rate & resolution

High-speed A/D conversion and powerful digital processing capability of 2400 times/sec. High display resolution of 1/100000 (max).
Measurement can be performed quickly and precisely due to the high speed A/D conversion.

 
Application software for USB interface

With communication through USB interface, logging, graph, display, setting parameters, and calibration can be done.

High performance filter & Auto filter adjustment

With combination of the low pass filter (0.1 to 600 Hz) which corresponds to various vibration and the moving average filter (OFF, 2 to 999) that is effective for periodic vibration, the automatic searching for optimal value with accuracy and stability can be achieved. (You can manually adjust the settings too).

Lightweight and compact body to fit into limited space in a control panel

Lightweight & compact body for 35mm DIN rail mount
Dimension: 34(W)×88(H)×91(D)mm (Not including projections)
Weight: Approx. 230g



Various interfaces



Input conversion value display

The output signal level of load cell can be displayed in mV/V for monitor purpose.
Malfunction indicator or faulty sensor can be differentiated easily.

6-digit display

24 bit A/D convertor enables 6-digit display.

Equivalent input calibration

Theoretical calibration can be performed easily by registering the capacity and rated output of load cells.

Digital peak & bottom hold, Hi & Lo functiont

Quickly captures any changes in high-speed phenomenon, and perform OK / NOK judgment.

Specifications

Analog section
Excitation voltage DC 5 V±5% Output current: Within 90 mA
DC 2.5 V±5% Output current: Within 45 mA
(depending on settings)
Ratiometric method (Up to 6 350 Ω load cells can be connected in parallel)
Signal input range -3.9 to +3.9 mV/V
Zero adjustment
range
Automatic adjustment by digital processing -3.0 to +3.0 mV/V
Span adjustment
range
Automatic adjustment by digital processing 0.01 to 3.8 mV/V
Min.
input sensitivity
0.15 μV/count
Accuracy Non-linearity: within 0.01% FS
Zero drift: 0.0002% FS/℃ Typ.
(When calibrated by 3 mV/V with 5 V of the excitation voltage)
Gain drift: 1 ppm/℃ Typ.
Filter Digital low-pass filter: 0.1 to 600 Hz
Moving average filter: OFF, 2 to 999 times
A/D converter Speed: 2400 times/sec.
Resolution: 24 bit (binary)
 
Display section
Display unit Character height 8 mm
Numerical display by 7-segment green LED
Display value Up to 6 digits
Display frequency Selectable from 1, 3, 6, 13, 25 times/sec.
Status display MS/NS
 
Hold functions
Hold Sample, Peak, Bottom, Peak & Bottom, Average
 
External signal
Output signal
(5)
Selectable/configurable
Transistor’s open collector output
Vceo = 30 V, Ic = 50 mA
Input signal
(3)
Selectable/configurable
Input is ON when shorted to COM terminal by contact (relay switch, etc.)
or non contact (transistor, open collector, etc.).
* DC 24 V external power supply is required.
 
Interface
PRT PROFINET IO interface
USB USB interface
 
General specifications
Power supply
voltage
DC 24 V (±15%)
Power
consumption
3 W typ.
Operating
conditions
Operating temperature range: -10 to +50℃
Storage temperature range: -20 to +85℃
Humidity: 85% RH or less (non-condensing)
Dimensions 34(W) × 88(H) × 91(D) mm (Not including projections)
Weight Approx. 230 g
CE marking
certification
EMC Directives EN61326-1
 
Attachments
Quick manual 2
Mini driver 1
Jumper wire 2
Various I/O connector 2
 
Optional accessories
CA81-USB USB cable (Type-A-Bmini) 1.8 m
CN85 13 p connector for power source/sensor/RS-485(SIF)
(Same as the attachment)
CN87 10 p connector for external I/O
(Same as the attachment)
 


Please note that there are possibilities of individual differences in a color tone on display devices such as LEDs, fluorescent display tubes and LCDs due to manufacturing process or production lots.


 

Download

Product catalogue(PDF)
⇒Download Page
Operation manual(PDF)
External dimension
DXF
(ZIP)
PDF
Support tools
Software